Cảm biến lưu lượng Festo SFAH-200U-Q8S-PNLK-PNVBA-L1 (Mã 8058477)

Part Number 8058477

SFAH-200U-Q8S-PNLK-PNVBA-L1

Cảm biến lưu lượng Festo SFAH-200U-Q8S-PNLK-PNVBA-L1 (Mã 8058477)

Flow sensor · Cảm biến

Gọi kỹ thuật 0964.032.890 Tải datasheet PDF

Liên hệ báo giá: dongluc.industry@gmail.com

Thông số kỹ thuật

Approval RCM c UL us - Listed (Oil)
CE mark (see declaration of conformity) To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity) To UK instructions for EMC To UK RoHS instructions
Note on materials RoHS compliant
Measured variable Mass ow rate Volumetric ow rate
Flow direction Unidirectional
Measuring principle thermal
Measurement method Heat transfer
Start value for ow rate measuring range 4 l/min
End value for ow rate measuring range 200 l/min
Operating pressure -0.9 bar...10 bar
Operating medium Argon Compressed air to ISO 8573-1:2010 [6:4:4] Nitrogen
Media temperature 0 °C...50 °C
Ambient temperature 0 °C...50 °C
Nominal temperature 23 °C
Accuracy of ow rate ± (2% o.m.v. + 1% FS)
Repetition accuracy offset in ± %FS 0.2 %FS
Repetition accuracy span in ± %FS 0.8 %FS
Temperature coefficient span in ± %FS/K typ. 0.15%FS/K
Pressure inuence range in ± %FS Typ. 1 %FS
Switching output 2 x PNP or 2 x NPN, switchable
Switching function Window comparator Threshold value comparator Auto difference monitoring
Switching element function NC or NO, switchable
Max. output current 100 mA
Flow characteristic curve start value 0 l/min
Flow characteristic curve end value 200 l/min
Max. load resistance current output 500 Ohm
Min. load resistance voltage output 20 kOhm
Short circuit current rating Yes
Overload protection Available
Protocol IO-Link®
IO-Link, Protocol version Device V 1.1
IO-Link, Prole Smart sensor prole
IO-Link, Function classes Binary data channel (BDC) Process data variable (PDV) Identication Diagnostics Teach channel
IO-Link, communication mode COM2 (38.4 kBaud)
IO-Link, SIO-Mode support Yes
IO-Link, Port class A
IO-Link, Process data length IN 3 bytes
IO-Link, Process data content IN 1 bit BDC (volume monitoring) 14 bit PDV (measured ow value) 2 bit BDC (ow monitoring)
IO-Link, Service data IN 32-bit volume / mass measured value
IO-Link, Min. cycle time 4 ms
IO-Link, Data storage required 0.5 KB
Operational voltage range DC 22 V...26 V
No-load supply current 25 mA
Reverse polarity protection For all electrical connections
Electrical connection 1, connection type Plug
Electrical connection 1, connector system Plug pattern L1J
Electrical connection 1, number of connections/cores 4
Type of mounting With accessories
Mounting position Any
Pneumatic connection For tubing O.D. 8 mm
Pneumatic connection, outlet direction Straight
Product weight 60 g
Material housing Reinforced PA
Material in contact with the medium Anodised wrought aluminium alloy Epoxy NBR Reinforced PA Silicon Silicon nitride High-alloy stainless steel
Display type Illuminated LCD, multi-colour
Displayable units g g/min l l/min scft scft/h scft/min
Setting options IO-Link® Teach-in Via display and buttons
Protection against tampering IO-Link® PIN code
Degree of protection IP40
Pressure drop 56 mbar
Protection class III
Corrosion resistance class CRC 2 - Moderate corrosion stress
LABS (PWIS) conformity VDMA24364-B2-L
Cleanroom suitability, measured according to ISO 14644-14 Class 4 according to ISO 14644-1

Tài liệu kỹ thuật (Datasheet)

Mở toàn màn hình ↗
Zalo f